CCPDF - 62-860062-000 PINSETTER GRAY, 50711W25

  • MSDS: CCPDF
  • Manufacturer: SPRAYON PRODUCTS
  • Product Name: 62-860062-000 PINSETTER GRAY, 50711W25
  • National Stock Number: 8010-00N073683
Product Identification

Product ID:62-860062-000 PINSETTER GRAY, 50711W25
MSDS Date:08/10/1994
FSC:8010
NIIN:00N073683
MSDS Number: CCPDF

Responsible Party
SPRAYON PRODUCTS
26300 FARGO AVE
BEDFORD HEIGHTS, OH 44146
US

Emergency Phone: 216-292-7400

Info Phone: 216-292-7400

Cage: 09800

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

760

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 11%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


760

CAS: 106-97-8

RTECS: EJ4200000

Fraction By Weight: 11%

OSHA PEL 800 PPM

ACGIH TLV: 800 PPM


53

CAS: 64742-89-8

Fraction By Weight: 2%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


22

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 6%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


33

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 1%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500 STEL


180

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 41%

OSHA PEL 1000 PPM

ACGIH TLV: 750 PPM/1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 2.81%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM/300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


47.50

CAS: 108-21-4

RTECS: AI4930000

Fraction By Weight: 4%

OSHA PEL 250 PPM

ACGIH TLV: 250 PPM/310 STEL


PROPIONIC ACID, 3-ETHOXY-, ETHYL ESTER;

CAS: 763-69-9

RTECS: UF3325000

Fraction By Weight: 7%

OSHA PEL N/K

ACGIH TLV: N/K


SYSTEMS. RPTS HAVE ASSOC RPTD & PRLNGD OVEREXP TO

RTECS: 9999999ZZ


BY DELIBERATELY CONCENTRATING & INHALING THE

RTECS: 9999999ZZ


APPLIC LIMS FOR NUISANCE DUSTS ARE ACGIH TLV 10

RTECS: 9999999ZZ


5 MG/M3 (RESPIRABLE FRACTION). KEEP AWAY FROM HEAT,

RTECS: 9999999ZZ


AND MAY IGNITE EXPLOSIVELY. DURING USE & UNTIL ALL

RTECS: 9999999ZZ


EXTING ALL FLAMES, PILOT LIGHTS, & HEATERS-TURN OFF

RTECS: 9999999ZZ


SOURCES OF IGNIT. CONSULT NFPA CODE. USE APPRVD

RTECS: 9999999ZZ


DO NOT PUNCTURE, INCIN/EXPOSE TO TEMP ABOVE 120F.

RTECS: 9999999ZZ


OTHER HEAT SOURCES COULD CAUSE CNTNR TO BURST. DO

RTECS: 9999999ZZ


NIOSH FOR DUST WHICH MAY BE GENERATED FROM THIS

RTECS: 9999999ZZ


REFER TO OSHA STANDARDS 1910.94, 1910.107, 1910.108.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSSIBLY DEATH. SIGNS & SYMPS OF OVEREXP:HDCH, DIZZ, NAUS, & LOSS
OF COORDINATION ARE INDICATIONS OF EXCESS EXPOS TO VAPS/SPRAY
MISTS. REDNESS & ITCHING/BURNING SENSATION MAY INDICATE EYE/EXCESS
SKIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EXPOS. CHRONIC:TOLUENE APPEARS ON THE
NAVY LISTING OF OCCUP CHEM REPROD HAZARDS. SEEK CONSULTATION FROM
APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZARD LIST INFO & SAFE
HNDLG & EXPOS INFO . METHYL ETHYL KETONE MAY INCR NERV SYS EFTS OF
OTHER SOLV. PRLNGD OVEREXP TO SOLV INGREDS IN SECTION II (SUPDAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER REMOVE CONTAMD
CLTHG & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LG AMTS OF WATER FOR AT
LEAST 15 MINS. GET MEDICAL ATTENTION. INGEST:GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point:<0F,<-18C
Lower Limits:1.0%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP . WATER
SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE PREF. WATER
MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELEC EQUIP, SPKS, &
OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT.
APPLIC TO HOT SURF REQS SPEC PREC. DURING EMER (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP
& SPRAY MIST. AVOID CONT W/SKIN & EYES.
Other Precautions:THIS COATING MAY CNTN MATLS CLASSIFIED AS NUISANCE
PARTICULATES (LISTED "AS DUST" IN INGRED SECTION) WHICH MAY BE
PRESENT @ HAZ LEVS ONLY DURING SANDING/ABRADING OF DRIED FILM. IF
NO SPECIFIC DUSTS AR E LISTED IN INGRED SECTION, (ING 12)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP
APPRVD BY NIOSH FOR PROT AGAINST MATLS IN INGRED SECTION. WHEN
SANDING/ABRADING DRIED FI LM, WEAR DUST/MIST RESP APPRVD (ING 19)
Ventilation:LOC EXHAUST PREF. GEN EXHAUST ACCEPTABLE IF EXPOS TO MATLS
IN INGRED SECTION IS MAINTAINED BELOW APPLIC LIMS. (ING 20)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FL PT:<0F,<-18C PROPELLANT. FIRE FIGHT PROC:PVNT PRESS BUILD-UP & POSS
AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:CNDTNS
OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED
APPARENT. OBTAIN MED ATTN. EFTS OF OVEREXP:MAY CAUSE ADVERSE EFTS
TO LIVER, URINARY, CARDIOVASCULAR & REPROD (ING 10)

Chemical Properties

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.75
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:91

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
RSRA 49 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM
APPLIC EPA HAZ WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE CNTNR.
DISPOSE OF I/A/W FEDER AL, STATE, & LOCAL REGS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.